MIL-DTL-6117L
4. VERIFICATION
4.1 Classification of inspections. The inspection requirements specified herein are
classified as follows:
a. Qualification inspection (see 4.2).
b. Conformance inspection (see 4.3).
4.2 Qualification inspection. The qualification inspection shall consist of all the tests
and examinations of this specification.
4.2.1 Qualification inspection samples. Qualification testing samples shall consist of a
wire rope assembly, 2 feet in length, for each of the following configurations:
a. MIL-DTL-83420/1-002 wire rope with a MS21260 terminal and a MS20667 fork
end terminal.
b. MIL-DTL-83420/1-003 wire rope with a MS21260 terminal and a MS20668 eye
end terminal.
c. MIL-DTL-83420/2-004 wire rope with a MS21260 terminal and a MS20667 fork
end terminal.
d. MIL-DTL-83420/2-003 wire rope with a MS21260 terminal and a MS20668 eye
end terminal.
e. MIL-DTL-83420/3-002 wire rope with a MS21260 terminal and a MS20667 fork
end terminal.
f. MIL-DTL-83420/3-003 wire rope with a MS21260 terminal and a MS20668 eye
end terminal.
g. MIL-DTL-83420/4-003 wire rope with a MS21260 terminal and a MS20667 fork
end terminal.
h. MIL-DTL-83420/1-009 wire rope with a MS21260 terminal and a MS20667 fork
end terminal.
i. MIL-DTL-83420/1-010 wire rope with a MS21260 terminal and a MS20668 eye
end terminal.
j. MIL-DTL-83420/2-012 wire rope with a MS21260 terminal and a MS20667 fork
end terminal.
k. MIL-DTL-83420/2-013 wire rope with a MS21260 terminal and a MS20668 eye
end terminal.
4.2.2 Qualification testing. Qualification testing shall be performed on two test samples
of each configuration and consist of the:
a. Examination of product (see 4.5.1).
b. Proof load test (see 4.3.2.2).
c. Breaking strength (see 4.6.1.1).